HIGH-TEMPERATURE WIRE
HIGH-TEMPERATURE WIRE
200°C – 600 Volts – UL Style 3512/3604 / CSA AWM I A/B FT2
200°C – 1000 Volts – UL Style 3644 / CSA AWM I A/B FT2
200°C – 600 Volts/200°C – 1000 Volts – UL Style 3604/3644 / CSA AWM I A/B FT2
RoHS Compliant
Conductors
22 AWG – 4/0 AWG
8 AWG – 4/0 AWG(DUAL RATED)
Stranded tinned copper or nickel-plated copper
(Other conductor materials available)
Insulating System
Composite Extruded Silicone Rubber with intermediate fiberglass reinforcement
Separator tape between conductor and silicone on select sizes
(Not shown in illustration)
Standard Color Coding
Available in Colors
Lead wire
Outperforms Braided Silicone products
Eliminates braid fraying, flowering, and shrink back
Virtually eliminates skin irritation
Reduces airborne fiberglass contaminants traditionally found in high volume processing
Superior flexibility
Color stable at elevated temperatures
LSZH: Low smoke, zero halogen
Suitable for varnish dip and bake applications
Silicone formulations suitable for UV, ozone, moisture exposure
Not suited for immersed applications
Suitable for applications to -60°C
PFAS-Free
150°C version with flexible stranded conductor is available.(consult factory)
Part No. Temp Rating Voltage Rating Awg. Size # Strands Final O.D. (in) Final O.D. (mm) Wgt. (lbs/Mft) Wgt. (kg/km) Min. Bend Radius (in) UL CSA NBA22P007 200C 600V 22 NPC 2% 7 0.099 2.51 6.53 9.72 0.79 3512/3604 AWM I A/B FT2 NBA20P007 200C 600V 20 NPC 2% 7 0.108 2.74 8.19 12.19 0.86 3512/3604 AWM I A/B FT2 NBA18T007 200C 600V 18 7 0.119 3.02 10.75 16.00 0.95 3512/3604 AWM I A/B FT2 NBA16T007 200C 600V 16 7 0.130 3.30 14.39 21.42 1.04 3512/3604 AWM I A/B FT2 NBA14T007 200C 600V 14 7 0.142 3.61 19.07 28.38 1.14 3512/3604 AWM I A/B FT2 NBA12T019 200C 600V 12 19 0.160 4.06 28.59 42.55 1.28 3512/3604 AWM I A/B FT2 NBA10T019 200C 600V 10 19 0.212 5.38 47.20 70.24 1.70 3512/3604 AWM I A/B FT2 NBA08T061 200C 600V 8 61 0.254 6.45 73.42 109.27 2.03 3512/3604 AWM I A/B FT2 NBA06T084 200C 600V 6 84 0.347 8.81 118.21 175.92 2.78 3512/3604 AWM I A/B FT2 NBA04T133 200C 600V 4 133 0.381 9.68 160.00 238.12 3.05 3512/3604 AWM I A/B FT2 NBA02T259 200C 600V 2 259 0.446 11.33 239.70 356.73 3.57 3512/3604 AWM I A/B FT2 NBA01T259 200C 600V 1 259 0.525 13.34 312.07 464.43 4.20 3512/3604 AWM I A/B FT2
Part No. Temp Rating Voltage Rating Awg. Size # Strands Final O.D. (in) Final O.D. (mm) Wgt. (lbs/Mft) Wgt. (kg/km) Min. Bend Radius (in) UL CSA NGA18T007 200C 1000V 18 7 0.119 3.02 10.75 16.00 0.95 3644 AWM I A/B FT2 NGA16T007 200C 1000V 16 7 0.130 3.30 14.39 21.42 1.04 3644 AWM I A/B FT2 NGA14T007 200C 1000V 14 7 0.142 3.61 19.07 28.38 1.14 3644 AWM I A/B FT2 NGA12T019 200C 1000V 12 19 0.160 4.06 28.59 42.55 1.28 3644 AWM I A/B FT2 NGA10T019 200C 1000V 10 19 0.212 5.38 47.19 70.23 1.70 3644 AWM I A/B FT2
Part No. Temp Rating Voltage Rating Awg. Size # Strands Final O.D. (in) Final O.D. (mm) Wgt. (lbs/Mft) Wgt. (kg/km) Min. Bend Radius (in) UL CSA NGA08T061 200C 600V/1000V 8 61 0.254 6.45 73.42 109.27 2.03 3604/3644 AWM I A/B FT2 NGA06T084 200C 600V/1000V 6 84 0.347 8.81 117.65 175.09 2.78 3604/3644 AWM I A/B FT2 NGA04T133 200C 600V/1000V 4 133 0.381 9.68 159.44 237.28 3.05 3604/3644 AWM I A/B FT2 NGA02T259 200C 600V/1000V 2 259 0.446 11.33 239.14 355.90 3.57 3604/3644 AWM I A/B FT2 NGA01T259 200C 600V/1000V 1 259 0.521 13.23 309.61 460.77 4.17 3604/3644 AWM I A/B FT2 NGAX1T259 200C 600V/1000V 1/0 259 0.576 14.63 391.34 582.41 4.61 3604/3644 AWM I A/B FT2 NGAX2T259 200C 600V/1000V 2/0 259 0.622 15.80 480.18 714.62 4.98 3604/3644 AWM I A/B FT2 NGAX3T259 200C 600V/1000V 3/0 259 0.671 17.04 590.84 879.31 5.37 3604/3644 AWM I A/B FT2 NGAX4T259 200C 600V/1000V 4/0 259 0.735 18.67 732.88 1090.70 5.88 3604/3644 AWM I A/B FT2
Standard conductor: Tinned Copper or Nickel Plated Copper (Standard conductor for 20-22 AWG Only: Nickrel Plated Copper – 2%)
Consult factory for alternative conductor and stranding options.